An open MRI is an imaging system with two or more open sides around the patient table. A strong magnetic field and radiofrequency pulses create detailed pictures of internal tissues without ionizing radiation, while the roomier design may feel less confined than a traditional scanner.
This overview explains the scanner’s design, imaging process, examination steps, positioning options, safety requirements, and reasons your clinician may recommend it before you schedule a scan.
Open MRI As A More Accessible Imaging Option
Two open sides distinguish this system from the long, narrow tunnel of a conventional scanner. You lie on a movable table while imaging equipment sits above you, beside you, or both above and beside your body. The added space can reduce the physical sensation of confinement.
A Different Scanner Shape
Magnetic resonance imaging produces pictures of the brain, spine, joints, abdomen, and other soft tissues. The scanner detects signals produced within your body rather than using X-rays. Because MRI does not use ionizing radiation, your examination avoids radiation exposure.
The open design does not change MRI’s basic purpose or imaging physics. It changes the space around your body, giving you more room to arrange your head, shoulders, hips, arms, or legs. That freedom can help when the standard bore feels too narrow or your examination requires a particular position.
Why You May Prefer More Space
Your choice may reflect anxiety, discomfort, or difficulty staying still in an enclosed scanner. Some examinations also require your arms to remain away from your torso. More space can make entry, breathing, and holding a position feel easier without changing the underlying image-acquisition process.
You still cannot assume that an open scanner suits every examination. The body part, required position, available coil, and necessary image detail all affect the choice. Ask the imaging center to confirm that its open system can perform the exact scan your clinician ordered.
The Technology Behind The Images
MRI works with hydrogen nuclei found in water and other substances throughout your body. The magnetic field aligns those nuclei, while radiofrequency pulses disturb their alignment. The scanner then detects signals released as the nuclei return toward their normal state.
From Magnetic Alignment to a Picture
Image creation has three connected stages: alignment, excitation, and detection. The magnetic field aligns hydrogen nuclei, and radiofrequency pulses send energy into the examined area. The scanner measures returning signals, including their strength and timing.
A computer converts those measurements into cross-sectional slices and, for some examinations, three-dimensional views. This process differs from ordinary photography because it maps signal patterns from your tissues. Those patterns can depict soft-tissue structures more clearly than standard X-ray pictures in the appropriate examination.
What the Scanner Sounds Like
You may hear knocking, tapping, clicking, and other loud sounds during image acquisition. These noises come from the scanner’s magnetic and radiofrequency equipment and are part of normal operation. Ear protection may be available, and your technologist can explain how you can communicate if the noise bothers you.
The same signal process operates in open and enclosed designs. Housing changes your access, positioning options, and comfort, but both systems still depend on magnetic alignment, radio signals, computer processing, and image formation. You may therefore hear similar equipment sounds in either environment.
Open and Closed MRI Designs Compared
Space surrounding your body is the main design difference. A closed MRI uses a long, narrow tube, while an open MRI leaves room around two or more sides of the table. Your positioning and comfort may change, but neither design automatically produces better images for every examination.
| Feature | Open MRI | Closed MRI |
|---|---|---|
| Space around you | Open on two or more sides | Longer, narrower enclosed opening |
| Positioning choices | Often offers more room to arrange your body | Uses a defined position inside the bore |
| Comfort in enclosed spaces | May feel less confined | May feel more enclosed |
| Scan options | Depends on the system and examination | Often supports a broad range of examinations |
| Image requirements | Must meet the purpose of the requested scan | Can be selected when its field strength or design is needed |
Width, Position, and Image Requirements
A knee examination may work well on an open table because your knee can sit near a suitable imaging coil. A head examination may require a dedicated head arrangement. Some scans need a closed system because its design supplies the field characteristics your clinician requires.
The word “open” does not automatically mean weaker, better, faster, or less accurate. Magnet strength, coil choice, software, body position, and clinical purpose all influence the result. Before your visit, confirm that the open system can deliver the images ordered for your examination.
What Happens During an Open MRI Examination
Your visit begins with a discussion of the examination and a safety screening. You then enter the scanning area, lie on the table, and remain still while the machine gathers signals from the body region under examination.
The Examination Sequence
- Check-in: Provide identification, appointment details, and relevant medical information to the imaging staff.
- Safety review: Discuss implants, medical devices, metal objects, and conditions that could affect the scan with your technologist.
- Positioning: Lie on the table so the technologist can place the examined body part near a specialized coil or imaging area.
- Instructions: Learn when to remain still, when to breathe normally, and how to signal a problem.
- Image acquisition: Remain in position while clicking and knocking sounds accompany data collection.
- Completion: Leave the table with assistance and learn how the images will be handled and who will discuss the results.
Your Role During the Scan
Movement can interfere with data collection, so maintaining the position selected by your technologist helps prevent blurred images. The technologist controls the scanner and table, while you communicate through an intercom, speaker, or call button. Report pain, dizziness, heating, or another concern immediately.
The open table supports your body and may move into the correct position. Separate imaging equipment creates the magnetic field, sends radiofrequency signals, and detects responses. Your technologist positions the examined tissue within that equipment’s working area so the scanner can collect useful data.
Reasons Clinicians May Recommend an Open Scan
Your clinician may select an open scanner when its available space helps you complete the examination comfortably. The decision also depends on the requested images, your ability to remain still, and the system’s capabilities rather than its appearance alone.
Comfort and Positioning
- Less confinement: Open space may ease anxiety during a long or repeated imaging session.
- Flexible positioning: More room may help arrange your head, shoulders, arms, hips, or legs.
- Breathing comfort: A wider setting may feel less restrictive, particularly during a lengthy examination.
- Claustrophobia: An open design may help when a tunnel-like scanner creates a strong feeling of confinement.
- Position adjustments: Extra space may permit small changes before imaging without rebuilding the entire setup.
- Body-part support: Joint, spine, head, and other scans may use open systems when the equipment meets imaging requirements.
A Practical Example
Suppose your clinician orders images of your shoulder. The technologist may place your shoulder inside a coil while you lie on your back or side. Open space can leave enough room to keep your arm and elbow in the requested position, although a head or abdominal scan may require different arrangements.
You should never assume that an ordered examination is available on any open machine. Equipment, field strength, coils, software, and scheduling capacity determine which scans the imaging center can perform. Confirming those details before arrival prevents a design mismatch.
Limits, Safety, and Questions To Ask Before Scanning
The scanner’s strong magnetic field creates specific screening requirements. Before entering the scanning area, you must disclose implants, metal-sensitive devices, foreign objects, and previous medical procedures so the staff can assess the relevant risks.
Safety Screening Is Essential
Bring a current list of your implants, devices, and medical conditions to your appointment. Never assume that a small metallic object is harmless because an open scanner has more space.
Certain implants or medical devices may require additional review, more information, or a different imaging method. Tell your technologist about cardiac devices, neurological implants, metal fragments, piercings, hearing aids, and anything else placed in or attached to your body. The technologist follows the center’s safety process and your clinician’s instructions.
Noise, Motion, and Communication
Knocking and tapping commonly accompany signal collection, even when the scanner has open sides. Ask about ear protection, and tell the staff before your scan if the equipment noise is likely to cause discomfort. Movement, breathing instructions, and sequence length can all affect your experience.
Your extra space does not remove the need for stillness or a specific coil. Confirm the practical details below before your appointment:
- Exact examination: Ask whether the imaging center can perform the scan ordered for your body part.
- Preparation: Confirm whether you must change clothing, remove jewelry, or follow other instructions.
- Safety review: Provide a complete list of implants, devices, allergies, and medical conditions.
- Comfort support: Describe claustrophobia, breathing concerns, pain, or difficulty remaining still.
- Communication: Learn how your technologist can hear or receive a signal during the scan.
- Results process: Clarify who will receive the images and who will explain the findings.
What to Remember
An open MRI combines magnetic fields and radiofrequency signals to create internal images without ionizing radiation, while two or more open sides provide more room around your body. Your best option depends on the examination, position, equipment, safety needs, and comfort. Confirm the center can perform your scan, and disclose everything metallic or implanted before the examination.
FAQ
Is an open MRI the same as a regular MRI?
Yes. Both use magnetic fields and radiofrequency signals to create internal images. Their physical designs differ, and that difference can affect positioning, space, comfort, and which examinations each system can perform.
Does an open MRI use radiation?
MRI scans don’t use ionizing radiation. The scanner uses a strong magnetic field and radiofrequency signals. You must still follow preparation and safety instructions because the magnetic field can create hazards around certain metal objects and implants.
Can an open MRI scan any body part?
No single design supports every body part equally. You need to confirm the requested examination with the imaging center, including the body part, required coil, positioning, and image detail.
Can I move during an open MRI?
You should follow the technologist’s instructions and remain still during image acquisition. Tell your technologist immediately about pain, dizziness, unusual heating, or any other concern.
What should I tell the imaging center before my scan?
Tell the staff about implants, medical devices, piercings, metal fragments, previous procedures, and any condition that may affect positioning or safety. Give your complete history rather than assuming an item is too small to mention.
How long does an open MRI examination take?
The duration depends on the body part, equipment, and image sequences involved. Arrival, safety screening, positioning, and leaving the facility add time beyond the scan itself, so ask the imaging center for an appointment-specific estimate.